{"product_id":"mobility-24v-8-amp-charger-power-first-pf2408lp-golden-technologies-part-mbe-0038","title":"PowerFirst PF2408LP 24V 8 Amp Mobility Scooter Charger - Golden Technologies MBE-0038","description":"\u003ch2 class=\"heading-color\"\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h2\u003e\n\u003cp\u003eThe PowerFirst PF2408LP is a premium, high-reliability 24V 8A smart battery charger, also sold as \u003cstrong\u003eGolden Technologies Part Number: MBE-0038\u003c\/strong\u003e. Designed for global efficiency, this 240W charger provides precise charging profiles for 24V lead acid or Gel cell type rechargeable batteries. Engineered specifically for harsh operating conditions, it is widely used for electric wheelchairs, mobility scooters (including the Golden Companion series), and medical equipment. It features an active variable-speed cooling fan for peak optimal performance and advanced electronic protection against short circuits and reverse polarity.\u003c\/p\u003e\n\u003cdetails class=\"remote-details\"\u003e\n\u003csummary class=\"remote-summary\"\u003e\n\u003ch3 style=\"display: inline;\" class=\"heading-color\"\u003e\u003cstrong\u003eImportant Note For Golden Companion Users| Please Check Your Battery Size\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/summary\u003e\n\u003caside\u003e\n\u003cp\u003eFor Golden Technologies Companion models GC340 (GC340B-S50) \u0026amp; GC440 (GC440B-S50), this 8-Amp charger (MBE-0038) is \u003cstrong\u003eONLY\u003c\/strong\u003e compatible if your scooter is equipped with \u003cstrong\u003e50Ah batteries\u003c\/strong\u003e. If your scooter is equipped with standard U1 batteries, you will need the 5-Amp charger instead (\u003cstrong\u003ePart Number: MBE-0037\u003c\/strong\u003e).\u003c\/p\u003e\n\u003c\/aside\u003e\n\u003c\/details\u003e\n\u003ch3 class=\"heading-color\"\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cdl class=\"remote-dl\"\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eBrands:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003ePowerFirst \/ Golden Technologies\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003ePowerFirst Model Number:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003ePF2408LP\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eGolden Technologies Part Number:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eMBE-0038\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eDC Output:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e24 VDC, 8A\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eMaximum DC Output Power:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e240 W\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eMaximum DC Output Voltage:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e33.6 V\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eDeep Discharge Recovery:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e10V (Minimum Voltage)\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eAC Input:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e100-240 VAC ±10%, 50\/60 Hz\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eMaximum AC Input Current:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e2.6 A\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eBattery Compatibility:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e24V lead acid or Gel cell type rechargeable batteries\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eCooling System:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eActive cooling with variable speed fan (DC 12V 0.12A, 40 x 10 mm)\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eProtections:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eReverse polarity (Electronic protection with auto-reset) and Short circuit (Electronic current limit)\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eDimensions:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e168 mm L x 95.2 mm W x 55 mm H\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e1 kg\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003cdetails class=\"remote-details\" open=\"\"\u003e\n\u003csummary class=\"remote-summary\"\u003e\n\u003ch3 style=\"display: inline;\" class=\"heading-color\"\u003e\u003cstrong\u003eMobility Scooter Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/summary\u003e\n\u003cdl class=\"remote-dl\"\u003e\n\u003cdt\u003e\n\u003cstrong class=\"heading-color\"\u003eCompatible Golden Technologies Models\u003c\/strong\u003e \u003cem\u003e(Requires 50Ah Batteries)\u003c\/em\u003e\n\u003c\/dt\u003e\n\u003cdd\u003e\n\u003cstrong\u003eCompanion Series:\u003c\/strong\u003e Model Numbers GC340, GC340B-S50, GC440, GC440B-S50\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"remote-details\"\u003e\n\u003csummary class=\"remote-summary\"\u003e\n\u003ch3 style=\"display: inline;\" class=\"heading-color\"\u003e\u003cstrong\u003eLED Indicator Functions Guide\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/summary\u003e\n\u003cdl class=\"remote-dl\"\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eYellow On (Power):\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eAC connected\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eYellow On (Charging):\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eNormal charging\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eGreen On:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eFully charged (Batteries ready for use)\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eYellow Flash:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eNo battery connected or Low voltage (\u0026lt;15V) detected from batteries connection\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eRed On or Flashing:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eBattery reversed polarity or Battery voltage (\u0026gt;30V) fault\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"remote-details\"\u003e\n\u003csummary class=\"remote-summary\"\u003e\n\u003ch3 style=\"display: inline;\" class=\"heading-color\"\u003e\u003cstrong\u003eUser Manual \u0026amp; Safety Instructions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/summary\u003e\n\u003col style=\"margin-left: 20px;\"\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eBefore use of the battery charger, please make sure to read and follow all safety instructions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eFailure to follow the warnings and instructions may result in electric shock, fire and\/or serious injury. Save all safety warnings and instructions for future reference.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eFor indoor use only, do not expose to rain, snow or damp conditions.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eCheck that there is no sign of damage to the case, cables and socket before using the charger. Contact your authorized dealer in the event of any damage.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eContact your authorized dealer if you are unsure of how to operate the charger.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eThe charger must be placed in a well ventilated area protected from direct sunlight and inflammable surfaces, paper textiles etc.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eTo reduce risk of fire hazard, do not cover or obstruct the ventilation holes on the charger.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eKeep the charger out of children's reach.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eCharge only 24V lead acid or Gel cell type rechargeable batteries.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eBefore each use, check the battery charger, cable and plug. If damage is detected, do not use the battery charger. Never open the battery charger yourself. Have repairs performed only by a qualified technician.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eDisconnect the AC Input supply before plugging or unplugging the connections to the battery.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eUnplug both of the DC output and the AC Input power cord of the charger when the batteries are fully charged.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eIt is normal for the charger to be warm to the touch and the temperature may exceed 41 degrees Celsius during the boost charging process. Do not make prolonged skin contact with the charger while charging!\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eTo properly use the battery charger first connect DC output plug of the charger with the charging port of the unit. Then connect AC plug on the charger into AC power outlet.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eThe charger is supplied with a polarized plug. The charging plug must not be dismantled or modified.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eWarning! Risk of electric shock. Do not attempt to open or modify this charger in any way. No user serviceable parts inside.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eWarning! Explosive gases. Prevent flames and sparks. Provide adequate ventilation during charging.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003eFor normal use, the charger requires no maintenance over and above general cleaning, which requires a soft cloth, which may be damp if necessary.\u003c\/li\u003e\n\u003cli style=\"margin-bottom: 0.5em;\"\u003ePower Cord EU (European Union) version: A certified power cord set must be used with this equipment. The relevant national installation and or equipment regulations shall be considered. A certified power supply cord not lighter ordinary polyvinyl chloride flexible cord according to 60227 IEC 52 (designation H03VV-F) shall be used. Alternatively, a flexible cord be of synthetic rubber according to 60245 IEC 53 (designation H05RR-F) shall be used. Power supply cord with conductors providing a cross-sectional area of 3G, 0.75mm² minimum.\u003c\/li\u003e\n\u003cli\u003ePower Cord USA and Canada version: A UL Certified grounding-type attachment plug rated 125 volts, 15 amp fitted with cord type SJT, SP-2, SPE-2, SV, SVE or SVT, with 18 AWG minimum has to be used with this equipment. Length of power supply cord 1.8m-3m required.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/details\u003e\n\u003cdetails class=\"remote-details\"\u003e\n\u003csummary class=\"remote-summary\"\u003e\n\u003ch3 style=\"display: inline;\" class=\"heading-color\"\u003e\u003cstrong\u003eCertifications \u0026amp; Operating Environment\u003c\/strong\u003e\u003c\/h3\u003e\n\u003c\/summary\u003e\n\u003cdl class=\"remote-dl\"\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eCE, CB, UKCA, BC, DOE, ROHS\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eMedical \u0026amp; Mobility Standards:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eMeets ISO 7176-21:2009 standard. Conforms to AAMI STD ES 60601-1 and certified to CSA STD C22.2 NO.60601-1\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eEnergy Efficiency:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eCalifornia Energy Commission (CEC) compliant\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eEnclosure Rating:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003eIP21\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e-20°C to +45°C (Derated at \u0026gt;45°C)\u003c\/dd\u003e\n\u003cdt class=\"remote-dt\"\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003c\/dt\u003e\n\u003cdd class=\"remote-dd\"\u003e-40°C to +60°C\u003c\/dd\u003e\n\u003c\/dl\u003e\n\u003c\/details\u003e","brand":"Golden Technologies","offers":[{"title":"Default Title","offer_id":52858920829228,"sku":"MBE-0038","price":249.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0737\/4392\/5548\/files\/power-first-pf2409lp-mobility-battery-charger-with-3-pin-xlr-golden-technologies-mbe-0038-top-with-cables.jpg?v=1776182254","url":"https:\/\/www.mobilemobilityservices.com\/products\/mobility-24v-8-amp-charger-power-first-pf2408lp-golden-technologies-part-mbe-0038","provider":"Mobile Mobility Service","version":"1.0","type":"link"}